Apollo 5 Plus System

The Apollo 5 Plus replacement mattress consists of a single set of alternating cells, supported by a covered foam base. The 'Very High Risk' mattress also boasts an easy to use pump that is both quiet and efficient, reducing the need for complex training.

The Apollo 5 Plus replacement mattress consists of a single set of alternating cells, supported by a covered foam base. The 'Very High Risk' mattress also boasts an easy to use pump that is both quiet and efficient, reducing the need for complex training.

  • Full replacement system
  • Adjustable weight settings
  • Designed for users at very high risk, or have existing tissue damage
  • Manual adjustment to user's body shape and position for optimum pressure care
  • Dynamic therapy alternating action for lower interface pressures and gentle capillary stimulation
  • Static Mode enables stable surface for safer patient transfers & handling
  • Humidity management to help prevent tissue breakdown and skin maceration
  • Multi-stretch PU cover is both waterproof and vapour permeable, reducing shear and friction, and can be easily wiped clean or completely removed for laundering
  • PU cover to prevent fluid ingress and internal mattress contamination
  • Provides 12 hours backup system to remain inflated during power failure or patient transport
  • Clinically effective against bacteria / viruses, with proven resistance to MRSA
  • Fire retardant to Standards BS7175 Crib 5
  • Clear and simple controls reduces need for complex training
  • External air filters for easier maintenance
  • Removable cells and connectors for lower cost servicing
  • Quick access CPR for emergency mattress deflation
  • High frequency welded seams reduce the risk of fluid ingress, supporting infection control protocols
  • Product Code: APH052
  • Mattress Dimensions (inflated): 200cm x 90cm x 17.5cm
  • Mattress Weight: 8 kg
  • Max. Weight Limit: 31.5 stone / 200 kg
  • Min. Weight Limit: 6 stone / 38 kg
  • Cell Configuration: 15 alternating cells plus 3 static head cells
  • Risk Factor: Very High Risk


Electrical

  • Pump Dimensions:  27.5cm x 13.5cm x 9cm
  • Pump Weight: 1.4 kg
  • Pressure Range: 30-80 mmHg
  • Cycle Time: 9.6 minutes
  • Power Supply: AC 220-240V 50Hz, 0.09A
  • Noise Level: Below NC27
  • Fuse Rating: 500mA
  • Medical Classification: Type BF Applied Part
  • EMC Standards: BS EN 60601-1, BS5724-1 (CE, FDA, TUV)