Apollo 8 System
The Apollo 8 replacement mattress consists of 17 ‘figure of 8’ alternating cells plus 3 static head cells that is designed for users at a 'Very High Risk' of developing pressure ulcers, or have existing tissue damage.
The Apollo 8 replacement mattress consists of 17 ‘figure of 8’ alternating cells plus 3 static head cells that is designed for users at a 'Very High Risk' of developing pressure ulcers, or have existing tissue damage. The system includes a welded cover that is washable up to 95 degrees ensuring the strictest infection control policies are adhered to. The easy to use pump reduces the need for complex training.
- Full replacement system
- Designed for users at very high risk, or have existing tissue damage
- Auto weight setting with manual comfort adjustment
- Constant Low Pressure provided to reduce pressure intensity
- Dynamic therapy alternating action for lower interface pressures and gentle capillary stimulation
- Max Inflate Mode enables stable surface for safer patient transfers and handling
- Humidity management to help prevent tissue breakdown and skin maceration
- Multi-stretch PU cover is both waterproof and vapour permeable, reducing shear and friction, and can be easily wiped clean or completely removed for laundering
- Waterproof with high vapour permeability for improved infection control
- High frequency welded seams reduce the risk of fluid ingress, supporting infection control protocols
- Provides 12 hours backup system to remain inflated during power failure or patient transport
- Clinically effective against bacteria / viruses, with proven resistance to MRSA
- Fire retardant to Standards BS7175 Crib 5
- Clear and simple controls reduces need for complex training
- External air filters for easier maintenance
- Removable cells and connectors for lower cost servicing
- Quick access CPR for emergency mattress deflation
- Audible and visual alarms
- Cable management loops
- Product Code: APH053/HERA
- Mattress Dimensions (inflated): 200cm x 90cm x 20 cm
- Mattress Weight: 9 kg
- Max. Weight Limit: 31.5 stone / 200 kg
- Cell Configuration: 17 'figure of 8' alternating cells plus 3 static head cells
- Risk Category: Very High Risk
Electrical
- Pump Dimensions: 28cm x 17cm x 12 cm
- Pump Weight: 1.8 kg
- Pressure Range: 30-50 mmHg
- Cycle Time: 10 minutes
- Power Supply: AC220 - 240V 50Hz, 0.09A
- Fuse Rating: T1AH 250V
- Medical Classification: Type BF Applied Part
- EMC Standards: IEC 60601-1-2, EN 60601-1-2, IEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3